High pressure units for air humidification
Features of the high pressure pump
Pump head corrosion resistant brass
Plunger hard ceramic (solid)
- Stainless steel valves, valve seats and springs
- Seals made of a special material
- Integrated leakage recirculation
- Quiet running
- Crankcase made of a die-cast aluminum
- Forged CrMo steel crankshaft
Functions
Supply voltage 230 V (single-phase)
- Lockable main switch
- Potentiometer for setting the operating pressure
- Pressure transmitter for the detection of the actual pressure
External potential-free release (start/stop)
- Optionally possible with standby operation (external release not necessary)
3 m cable with straight plug
- Stainless steel base plate
Functional description
As soon as the start signal is given externally, the frequency inverter regulates exactly to the operating pressure set at the potentiometer. In the event of changing consumption quantities (switching nozzles off or on), the speed and thus the flow rate are adapted to the demand.